This test is used to determine that the test flame will not ignite the part under the specified conditions, or the test flame ignites the combustible part, but the burning duration or burning length of the part is limited, and the flame or falling from the test sample The burning or hot particles will not spread the combustion.
Glow wire, needle flame and other material test areas:
Glow wire flammability test method of finished products (IEC60965-2-11: 2000/GB/T5169.11-2006)
Glow-wire flammability test method of materials (IEC60965-2-12: 2000/GB/T5169.12-2006)
Test method for glow-wire emergence of materials (IEC60965-2-13: 2000/GB/T5169.13-2006)
According to IEC60695-11-5; GB/T5169.5-2008, GB4706.1-2005